Banner

Sample Network and Multi-Channel Configuration Files

The *.cfg files listed below should be passed to Prepar3D® using the -net command line switch.

Prepar3d.exe -net:d:\IGConfig\IGMaster.cfg


The SimIG_*.xml files listed below should either be copied to c:\Users\YOURALIAS\AppData\Roaming\Lockheed Martin\Prepar3d\SimIG.XML or passed to Prepar3D® using the -ig command line switch.

Prepar3d.exe -ig:d:\IGConfig\SimIG_Circular_14Screens_7Slaves.xml


Multiplayer config files

These config files are located at SDK\Sample Network and MultiChannel Config Files\Multiplayer\. These files are for launching standard Multiplayer sessions from the command line.

File Description
MPHost.cfg This file is used to start a multiplayer host session. You will probably also want to use a "-flt:d:\Some\Path\filename.flt" to specify what vehicle the host is using and where the host is located.
MPClient1.cfg
to
MPClient6.cfg
These files are used to join clients to a multiplayer session. All of these are setup to share their aircraft.
MPShare1.cfg
to
MPShare6.cfg
These files are used to join clients to a multiplayer session and join another clients shared aircraft.  They join the client with the same suffix number.

Flat Wall mode Multi-Channel config files

These config files are located at SDK\Sample Network and MultiChannel Config Files\MultiChannel Flat Wall Mode\. These files are for launching a Multi-Channel session in Flat Wall mode.

File Description
IGMaster.cfg This file is used to start a Multi-Channel session host.
IGSlave0.cfg
to
IGSlave13.cfg
These files are used to start the Multi-Channel session slaves.
SimIG_2x2AutoGrid_4Slaves.xml This file defines a 2 wide by 2 high auto defined grid using 4 slave computers.
SimIG_2x2ManualGrid_2Slaves.xml This file defines a 2 wide by 2 high manual grid using 2 slave computers.

Circular mode Multi-Channel config files

These config files are located at SDK\Sample Network and MultiChannel Config Files\MultiChannel Circular Mode\. These files are for launching a Multi-Channel session in Circular mode.

File Description
IGMaster.cfg This file is used to start a Multi-Channel session host.
IGSlave0.cfg
to
IGSlave13.cfg
These files are used to start the Multi-Channel session slaves.
SimIG_Circular_14Screens_14Slaves.xml This file defines a 14 screen full circle using 14 slave computers.
SimIG_Circular_14Screens_7Slaves.xml This file defines a 14 screen full circle using 7 slave computers.


Copyright 2011 Lockheed Martin